CFS Structural Systems Fabrication · Delivery · Install
Call US Office +1 (978) 456-0770

Project Record

Campello

CFS exterior wall panels for the Redevelopment of Campello Apartments — Phase 1 at 1380 Main Street in Brockton, Massachusetts.

Project Overview

CFS System
Walls Exterior wall panels · 600S162-43 (18 ga) at 16" O.C.
Project Scale
194 CFS Panels 84 Level 1 · 110 Level 2 · Building 1 Phase 1
Location
Brockton MA
Technology
FRAMECAD FRAMECAD Structure design to AISI S100-16 LRFD

Scope

CFS work completed for this project

  1. 01

    Phase 1 exterior wall package

    Wall layout plans and FRAMECAD panel sheets for Building 1 Phase 1 exterior walls, covering Level 1 panels L100–L183 and Level 2 panels L200–L309.

    194 CFS PANELS 84 LEVEL 1 110 LEVEL 2
  2. 02

    Exterior wall framing criteria

    Exterior walls framed with 6-inch cold-formed steel studs (600S162) at a minimum 18-gauge (43 mil) thickness, spaced 16 inches on center unless noted otherwise, conforming to ASTM A653 SS Grade 50 with G90 coating.

    600S162-43 16" O.C. AISI S240
  3. 03

    FRAMECAD panel detailing

    Individual FRAMECAD Structure panel sheets for the METALLEVE WALLS system, designed to AISI S100-16 LRFD under IBC 2021 LRFD loading, including opening and east-elevation height coordination recorded in the Phase 1 submittal revisions.

    FRAMECAD STRUCTURE AISI S100-16 LRFD IBC 2021 LRFD